WEKO3
アイテム
{"_buckets": {"deposit": "6865e746-d9bc-43da-81e1-4fc29c29df3e"}, "_deposit": {"id": "22596", "owners": [], "pid": {"revision_id": 0, "type": "depid", "value": "22596"}, "status": "published"}, "_oai": {"id": "oai:repository.dl.itc.u-tokyo.ac.jp:00022596", "sets": ["1997", "1999"]}, "item_4_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "1965-12-01", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "12", "bibliographicPageEnd": "325", "bibliographicPageStart": "319", "bibliographicVolumeNumber": "17", "bibliographic_titles": [{"bibliographic_title": "生産研究"}]}]}, "item_4_description_13": {"attribute_name": "フォーマット", "attribute_value_mlt": [{"subitem_description": "application/pdf", "subitem_description_type": "Other"}]}, "item_4_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "自動車の自動変速機に併用されるターボ式流体伝動裝置の振動特性を解析する場合,軸の回転速度変動を測定する必要にせまられた.回転速度変動が微小で,しかも,1回転について1回,または,それ以上の早いものを測定することは比較的困難である.そこで,圧電式加速度計をトランスデューサとして用い,FM送信機を回転軸中に組み込んで,信号をテレメータする方法を開発した.", "subitem_description_type": "Abstract"}]}, "item_4_publisher_20": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "東京大学生産技術研究所"}]}, "item_4_source_id_10": {"attribute_name": "書誌レコードID", "attribute_value_mlt": [{"subitem_source_identifier": "AN00127075", "subitem_source_identifier_type": "NCID"}]}, "item_4_source_id_8": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0037105X", "subitem_source_identifier_type": "ISSN"}]}, "item_4_subject_15": {"attribute_name": "日本十進分類法", "attribute_value_mlt": [{"subitem_subject": "500", "subitem_subject_scheme": "NDC"}]}, "item_4_text_21": {"attribute_name": "出版者別名", "attribute_value_mlt": [{"subitem_text_value": "Institute of Industrial Science. University of Tokyo"}]}, "item_4_text_34": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"subitem_text_value": "Departmental Bulletin Paper"}]}, "item_4_text_4": {"attribute_name": "著者所属", "attribute_value_mlt": [{"subitem_text_value": "東京大学生産技術研究所 流体力学振動工学"}, {"subitem_text_value": "東京大学生産技術研究所 ディジタル通信方式"}, {"subitem_text_value": "Institute of Industrial Science. University of Tokyo"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "江守, 一郎"}], "nameIdentifiers": [{"nameIdentifier": "114317", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "横山, 茂士"}], "nameIdentifiers": [{"nameIdentifier": "114318", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "斎藤, 治彦"}], "nameIdentifiers": [{"nameIdentifier": "114319", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2017-06-26"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "sk017012002.pdf", "filesize": [{"value": "1.2 MB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 1200000.0, "url": {"label": "sk017012002.pdf", "url": "https://repository.dl.itc.u-tokyo.ac.jp/record/22596/files/sk017012002.pdf"}, "version_id": "2739de5d-bc24-41fc-94f7-0be8b301a2a5"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "departmental bulletin paper", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "回転速度変動の無接触測定装置", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "回転速度変動の無接触測定装置"}]}, "item_type_id": "4", "owner": "1", "path": ["1997", "1999"], "permalink_uri": "http://hdl.handle.net/2261/31562", "pubdate": {"attribute_name": "公開日", "attribute_value": "2009-12-24"}, "publish_date": "2009-12-24", "publish_status": "0", "recid": "22596", "relation": {}, "relation_version_is_last": true, "title": ["回転速度変動の無接触測定装置"], "weko_shared_id": null}
回転速度変動の無接触測定装置
http://hdl.handle.net/2261/31562
http://hdl.handle.net/2261/3156270fec6d4-b7a8-4bde-bf5a-3a323ba656ef
名前 / ファイル | ライセンス | アクション |
---|---|---|
sk017012002.pdf (1.2 MB)
|
|
Item type | 紀要論文 / Departmental Bulletin Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2009-12-24 | |||||
タイトル | ||||||
タイトル | 回転速度変動の無接触測定装置 | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源 | http://purl.org/coar/resource_type/c_6501 | |||||
タイプ | departmental bulletin paper | |||||
著者 |
江守, 一郎
× 江守, 一郎× 横山, 茂士× 斎藤, 治彦 |
|||||
著者所属 | ||||||
著者所属 | 東京大学生産技術研究所 流体力学振動工学 | |||||
著者所属 | ||||||
著者所属 | 東京大学生産技術研究所 ディジタル通信方式 | |||||
著者所属 | ||||||
著者所属 | Institute of Industrial Science. University of Tokyo | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | 自動車の自動変速機に併用されるターボ式流体伝動裝置の振動特性を解析する場合,軸の回転速度変動を測定する必要にせまられた.回転速度変動が微小で,しかも,1回転について1回,または,それ以上の早いものを測定することは比較的困難である.そこで,圧電式加速度計をトランスデューサとして用い,FM送信機を回転軸中に組み込んで,信号をテレメータする方法を開発した. | |||||
書誌情報 |
生産研究 巻 17, 号 12, p. 319-325, 発行日 1965-12-01 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0037105X | |||||
書誌レコードID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AN00127075 | |||||
フォーマット | ||||||
内容記述タイプ | Other | |||||
内容記述 | application/pdf | |||||
日本十進分類法 | ||||||
主題 | 500 | |||||
主題Scheme | NDC | |||||
出版者 | ||||||
出版者 | 東京大学生産技術研究所 | |||||
出版者別名 | ||||||
Institute of Industrial Science. University of Tokyo |