{"created":"2023-11-30T07:31:29.001016+00:00","id":2008236,"links":{},"metadata":{"_buckets":{"deposit":"9773fb38-a1df-4ccd-a65f-665e696f6840"},"_deposit":{"created_by":18,"id":"2008236","owner":"18","owners":[18],"pid":{"revision_id":0,"type":"depid","value":"2008236"},"status":"published"},"_oai":{"id":"oai:repository.dl.itc.u-tokyo.ac.jp:02008236","sets":["312:8042","9:7435:7436"]},"author_link":[],"item_8_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2023-10-26","bibliographicIssueDateType":"Issued"},"bibliographicVolumeNumber":"LMSR2023-21","bibliographic_titles":[{"bibliographic_title":"数理科学実践研究レター","bibliographic_titleLang":"ja"}]}]},"item_8_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"熱交換器の制御において、熱伝達率が不連続に変化するドライアウトポイントを予測することは重要である。本研究では熱交換器を単純な擬二次元系でモデル化し液膜の蒸発を数値シミュレーションを用いて解析した。熱流束を制御した場合の液膜の蒸発の様子を壁の濡れ確率を用いて評価し、その振る舞いを通してモデル中の液膜の蒸発の様子を評価した。","subitem_description_language":"ja","subitem_description_type":"Abstract"}]},"item_8_identifier_registration":{"attribute_name":"ID登録","attribute_value_mlt":[{"subitem_identifier_reg_text":"10.15083/0002008236","subitem_identifier_reg_type":"JaLC"}]},"item_8_publisher_20":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"東京大学大学院数理科学研究科","subitem_publisher_language":"ja"}]},"item_8_text_4":{"attribute_name":"著者所属","attribute_value_mlt":[{"subitem_text_language":"ja","subitem_text_value":"東京大学大学院総合文化研究科"},{"subitem_text_language":"en","subitem_text_value":"Graduate School of Arts and Sciences, The University of Tokyo"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorAffiliations":[{"affiliationNames":[{"affiliationName":"東京大学","affiliationNameLang":"ja"},{"affiliationName":"The University of Tokyo","affiliationNameLang":"en"}]}],"creatorNames":[{"creatorName":"中西, 亮","creatorNameLang":"ja"},{"creatorName":"Nakanishi, Ryo","creatorNameLang":"en"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_access","date":[{"dateType":"Available","dateValue":"2022-11-30"}],"displaytype":"detail","filename":"LMSR2023-21.pdf","filesize":[{"value":"1.3 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"objectType":"fulltext","url":"https://repository.dl.itc.u-tokyo.ac.jp/record/2008236/files/LMSR2023-21.pdf"},"version_id":"6afbf12b-e080-4942-b721-f12f5c7ed88a"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"technical report","resourceuri":"http://purl.org/coar/resource_type/c_18gh"}]},"item_title":"熱交換器における管壁上の液膜の蒸発のシミュレーション ドライアウトポイントの特定に向けて","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"熱交換器における管壁上の液膜の蒸発のシミュレーション ドライアウトポイントの特定に向けて","subitem_title_language":"ja"}]},"item_type_id":"8","owner":"18","path":["8042","7436"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2022-11-30"},"publish_date":"2022-11-30","publish_status":"0","recid":"2008236","relation_version_is_last":true,"title":["熱交換器における管壁上の液膜の蒸発のシミュレーション ドライアウトポイントの特定に向けて"],"weko_creator_id":"18","weko_shared_id":-1},"updated":"2023-11-30T07:31:41.789956+00:00"}