{"created":"2021-03-01T06:40:40.997359+00:00","id":22933,"links":{},"metadata":{"_buckets":{"deposit":"4773132e-9ac0-4ff5-8368-22e8d56c53dc"},"_deposit":{"id":"22933","owners":[],"pid":{"revision_id":0,"type":"depid","value":"22933"},"status":"published"},"_oai":{"id":"oai:repository.dl.itc.u-tokyo.ac.jp:00022933","sets":["171:1108:2048:2066","9:504:1111:2050:2067"]},"item_4_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"1963-04-01","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"4","bibliographicPageEnd":"106","bibliographicPageStart":"101","bibliographicVolumeNumber":"15","bibliographic_titles":[{"bibliographic_title":"生産研究"}]}]},"item_4_description_13":{"attribute_name":"フォーマット","attribute_value_mlt":[{"subitem_description":"application/pdf","subitem_description_type":"Other"}]},"item_4_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"本文では低雑音増幅を目的としたダイオード型パラメトリック増幅器について解説する.そのため低雑音増幅ができると,どのような利点があるかについて簡単に述べ,つぎにポンプ電圧を加えたダイオードの等価回路を求め,その等価回路を使って,増幅器の雑音特性を最良にする方法を説明した.","subitem_description_type":"Abstract"}]},"item_4_publisher_20":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"東京大学生産技術研究所"}]},"item_4_source_id_10":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AN00127075","subitem_source_identifier_type":"NCID"}]},"item_4_source_id_8":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0037105X","subitem_source_identifier_type":"ISSN"}]},"item_4_subject_15":{"attribute_name":"日本十進分類法","attribute_value_mlt":[{"subitem_subject":"500","subitem_subject_scheme":"NDC"}]},"item_4_text_21":{"attribute_name":"出版者別名","attribute_value_mlt":[{"subitem_text_value":"Institute of Industrial Science. University of Tokyo"}]},"item_4_text_4":{"attribute_name":"著者所属","attribute_value_mlt":[{"subitem_text_value":"東京大学生産技術研究所 応用電子工学"},{"subitem_text_value":"Institute of Industrial Science. University of Tokyo"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"黒川, 兼行"}],"nameIdentifiers":[{"nameIdentifier":"114979","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2017-06-26"}],"displaytype":"detail","filename":"sk015004003.pdf","filesize":[{"value":"645.9 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"sk015004003.pdf","url":"https://repository.dl.itc.u-tokyo.ac.jp/record/22933/files/sk015004003.pdf"},"version_id":"f2ea7e63-3b9f-4bdd-809d-8517c81956d5"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"ダイオード型パラメトリック増幅器","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"ダイオード型パラメトリック増幅器"}]},"item_type_id":"4","owner":"1","path":["2066","2067"],"pubdate":{"attribute_name":"公開日","attribute_value":"2009-12-24"},"publish_date":"2009-12-24","publish_status":"0","recid":"22933","relation_version_is_last":true,"title":["ダイオード型パラメトリック増幅器"],"weko_creator_id":"1","weko_shared_id":null},"updated":"2022-12-19T03:59:52.577033+00:00"}