{"created":"2021-03-01T06:42:20.736772+00:00","id":24468,"links":{},"metadata":{"_buckets":{"deposit":"56f7c231-3957-4e4d-93a5-39a8945d2ea7"},"_deposit":{"id":"24468","owners":[],"pid":{"revision_id":0,"type":"depid","value":"24468"},"status":"published"},"_oai":{"id":"oai:repository.dl.itc.u-tokyo.ac.jp:00024468","sets":["171:1108:2334:2346","9:504:1111:2336:2347"]},"item_4_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"1952-07-01","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"7","bibliographicPageEnd":"276","bibliographicPageStart":"273","bibliographicVolumeNumber":"4","bibliographic_titles":[{"bibliographic_title":"生産研究"}]}]},"item_4_description_13":{"attribute_name":"フォーマット","attribute_value_mlt":[{"subitem_description":"application/pdf","subitem_description_type":"Other"}]},"item_4_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"10,000Mcというと波長3.Ocmの極あて短かい電磁波のことであるが,この波長はレーダー等に廣く用いられている.これはこのような極超短波における電氣絶縁物の誘電率や損失,導波管,同軸ケーブルの損失を測定する裝置について述べたものである.","subitem_description_type":"Abstract"}]},"item_4_publisher_20":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"誠文堂新光社"}]},"item_4_source_id_10":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AN00127075","subitem_source_identifier_type":"NCID"}]},"item_4_source_id_8":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0037105X","subitem_source_identifier_type":"ISSN"}]},"item_4_subject_15":{"attribute_name":"日本十進分類法","attribute_value_mlt":[{"subitem_subject":"500","subitem_subject_scheme":"NDC"}]},"item_4_text_4":{"attribute_name":"著者所属","attribute_value_mlt":[{"subitem_text_value":"東京大学生産技術研究所 超短波工學 高周波應用"},{"subitem_text_value":"Institute of Industrial Science. University of Tokyo"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"齋藤, 成文"}],"nameIdentifiers":[{"nameIdentifier":"117504","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2017-06-26"}],"displaytype":"detail","filename":"sk004007013.pdf","filesize":[{"value":"1.0 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"sk004007013.pdf","url":"https://repository.dl.itc.u-tokyo.ac.jp/record/24468/files/sk004007013.pdf"},"version_id":"d2bf3182-ef74-4233-9cb0-32d20aa17fdb"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"10,000Mcにおける誘電體特性,傳送回路損失測定裝置","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"10,000Mcにおける誘電體特性,傳送回路損失測定裝置"}]},"item_type_id":"4","owner":"1","path":["2346","2347"],"pubdate":{"attribute_name":"公開日","attribute_value":"2009-12-18"},"publish_date":"2009-12-18","publish_status":"0","recid":"24468","relation_version_is_last":true,"title":["10,000Mcにおける誘電體特性,傳送回路損失測定裝置"],"weko_creator_id":"1","weko_shared_id":null},"updated":"2022-12-19T04:02:48.279963+00:00"}