{"created":"2021-03-01T06:20:31.206864+00:00","id":3868,"links":{},"metadata":{"_buckets":{"deposit":"df0fc094-69aa-4917-9b08-5e18a3ce9188"},"_deposit":{"id":"3868","owners":[],"pid":{"revision_id":0,"type":"depid","value":"3868"},"status":"published"},"_oai":{"id":"oai:repository.dl.itc.u-tokyo.ac.jp:00003868","sets":["110:255:256","9:233:234"]},"item_7_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2011-03-24","bibliographicIssueDateType":"Issued"},"bibliographic_titles":[{}]}]},"item_7_date_granted_25":{"attribute_name":"学位授与年月日","attribute_value_mlt":[{"subitem_dategranted":"2011-03-24"}]},"item_7_degree_name_20":{"attribute_name":"学位名","attribute_value_mlt":[{"subitem_degreename":"修士(環境学)"}]},"item_7_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"In this reserch, the introduction of a flat tube heat exchanger to the residential air conditioner is considered. The flat tube multi-flow type heat exchanger is considered to be the ideal heat exchanger when the new environmental-friendly refrigerant, HFO1234yf is introduced in the residential air-conditioning system because it can reduce the larger pressure drop of the HFO. However, this new heat exchangers have some problems in being introduced in the existing system. I would like to solve these problems by experiments and simulating the heat exchanger and the whole system.","subitem_description_type":"Abstract"}]},"item_7_full_name_3":{"attribute_name":"著者別名","attribute_value_mlt":[{"nameIdentifiers":[{"nameIdentifier":"9012","nameIdentifierScheme":"WEKO"}],"names":[{"name":"タナカ, チトセ"}]}]},"item_7_select_21":{"attribute_name":"学位","attribute_value_mlt":[{"subitem_select_item":"master"}]},"item_7_subject_13":{"attribute_name":"日本十進分類法","attribute_value_mlt":[{"subitem_subject":"528","subitem_subject_scheme":"NDC"}]},"item_7_text_24":{"attribute_name":"研究科・専攻","attribute_value_mlt":[{"subitem_text_value":"新領域創成科学研究科環境学研究系人間環境学専攻"}]},"item_7_text_27":{"attribute_name":"学位記番号","attribute_value_mlt":[{"subitem_text_value":"修創域第3974号"}]},"item_7_text_4":{"attribute_name":"著者所属","attribute_value_mlt":[{"subitem_text_value":"東京大学大学院新領域創成科学研究科環境学研究系人間環境学専攻"},{"subitem_text_value":"Department of Human and Engineered Environmental Studies, Graduate School of Frontier Sciences, The University of Tokyo"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"田中, 千歳"}],"nameIdentifiers":[{"nameIdentifier":"9011","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2017-05-31"}],"displaytype":"detail","filename":"K-02851-a.pdf","filesize":[{"value":"662.9 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"要旨(summary)","url":"https://repository.dl.itc.u-tokyo.ac.jp/record/3868/files/K-02851-a.pdf"},"version_id":"42d08d8d-29e1-4073-bf51-e1ee9668ad96"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"Heat Pump","subitem_subject_scheme":"Other"},{"subitem_subject":"Mutli-flow","subitem_subject_scheme":"Other"},{"subitem_subject":"HFO1234yf","subitem_subject_scheme":"Other"},{"subitem_subject":"Refrigerant","subitem_subject_scheme":"Other"},{"subitem_subject":"COP","subitem_subject_scheme":"Other"},{"subitem_subject":"Air-Conditioning","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"thesis","resourceuri":"http://purl.org/coar/resource_type/c_46ec"}]},"item_title":"ルームエアコン熱交換器の低圧損化の基礎研究(要旨)","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"ルームエアコン熱交換器の低圧損化の基礎研究(要旨)"}]},"item_type_id":"7","owner":"1","path":["234","256"],"pubdate":{"attribute_name":"公開日","attribute_value":"2012-10-12"},"publish_date":"2012-10-12","publish_status":"0","recid":"3868","relation_version_is_last":true,"title":["ルームエアコン熱交換器の低圧損化の基礎研究(要旨)"],"weko_creator_id":"1","weko_shared_id":null},"updated":"2022-12-19T03:45:34.936642+00:00"}