{"created":"2021-03-01T06:16:59.324172+00:00","id":448,"links":{},"metadata":{"_buckets":{"deposit":"b5097a74-9514-43ac-8a3a-46c3c69b5e6a"},"_deposit":{"id":"448","owners":[],"pid":{"revision_id":0,"type":"depid","value":"448"},"status":"published"},"_oai":{"id":"oai:repository.dl.itc.u-tokyo.ac.jp:00000448","sets":["30:31","9:10:14"]},"item_2_alternative_title_1":{"attribute_name":"その他のタイトル","attribute_value_mlt":[{"subitem_alternative_title":"Calibration Method of Visual Parameters of See-Through Head-Mounted Display to Adjust Apparent Distance"}]},"item_2_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"1995-05","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"4","bibliographicPageEnd":"582","bibliographicPageStart":"580","bibliographicVolumeNumber":"13","bibliographic_titles":[{"bibliographic_title":"日本ロボット学会誌"}]}]},"item_2_description_13":{"attribute_name":"フォーマット","attribute_value_mlt":[{"subitem_description":"application/pdf","subitem_description_type":"Other"}]},"item_2_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"For the purpose of coinciding the virtual environment displayed by See-Through Head-Mounted Display(STHMD) with the actual environment, a new calibration method is proposed. The method is for the calibration of the difference between supposed position and actual,position of the user's viewpoint, which is mainly caused by the individual difference of inter-pupil distance. This method is efficient to minimize the error concerning distance. The efficiency is evaluated by sensitivity analysis of visual parameters. It is also confirmed by experiment in which visual parameters of STHNID are calibrated individually, and the calibrated virtual environment matched the actual environment.","subitem_description_type":"Abstract"}]},"item_2_full_name_3":{"attribute_name":"著者別名","attribute_value_mlt":[{"nameIdentifiers":[{"nameIdentifier":"106554","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Ohkura, Michiko"}]},{"nameIdentifiers":[{"nameIdentifier":"106555","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Oishi, Takashi"}]},{"nameIdentifiers":[{"nameIdentifier":"106556","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Tachi, Susumu"}]}]},"item_2_publisher_20":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"日本ロボット学会"}]},"item_2_source_id_10":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AN00141189","subitem_source_identifier_type":"NCID"}]},"item_2_source_id_8":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"02891824","subitem_source_identifier_type":"ISSN"}]},"item_2_subject_15":{"attribute_name":"日本十進分類法","attribute_value_mlt":[{"subitem_subject":"548.3","subitem_subject_scheme":"NDC"}]},"item_2_text_4":{"attribute_name":"著者所属","attribute_value_mlt":[{"subitem_text_value":"東京大学先端科学技術研究センター"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"大倉, 典子"}],"nameIdentifiers":[{"nameIdentifier":"106551","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"大石, 峰士"}],"nameIdentifiers":[{"nameIdentifier":"106552","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"舘, 暲"}],"nameIdentifiers":[{"nameIdentifier":"106553","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2017-06-26"}],"displaytype":"detail","filename":"1304B132.pdf","filesize":[{"value":"200.6 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"1304B132.pdf","url":"https://repository.dl.itc.u-tokyo.ac.jp/record/448/files/1304B132.pdf"},"version_id":"d5314afd-49ae-4084-be93-b7984cd506cf"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"Tele-Existence","subitem_subject_scheme":"Other"},{"subitem_subject":"Virtual Reality See-Through Head-Mounted Display","subitem_subject_scheme":"Other"},{"subitem_subject":"Calibration Of Visual Parameters","subitem_subject_scheme":"Other"},{"subitem_subject":"Distance","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"シースルー型HMDにおける視覚パラメータの距離に関する較正法","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"シースルー型HMDにおける視覚パラメータの距離に関する較正法"}]},"item_type_id":"2","owner":"1","path":["31","14"],"pubdate":{"attribute_name":"公開日","attribute_value":"2010-03-12"},"publish_date":"2010-03-12","publish_status":"0","recid":"448","relation_version_is_last":true,"title":["シースルー型HMDにおける視覚パラメータの距離に関する較正法"],"weko_creator_id":"1","weko_shared_id":null},"updated":"2022-12-19T03:41:19.974807+00:00"}