WEKO3
アイテム
{"_buckets": {"deposit": "6c1b6e3f-80d8-45d7-82a0-6a9e255b2437"}, "_deposit": {"id": "20171", "owners": [], "pid": {"revision_id": 0, "type": "depid", "value": "20171"}, "status": "published"}, "_oai": {"id": "oai:repository.dl.itc.u-tokyo.ac.jp:00020171", "sets": ["1540", "1541"]}, "item_4_alternative_title_1": {"attribute_name": "その他のタイトル", "attribute_value_mlt": [{"subitem_alternative_title": "Adsorption Cooling by Utilizing Low-Temperature Heat"}]}, "item_4_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "1984-05-01", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "5", "bibliographicPageEnd": "214", "bibliographicPageStart": "205", "bibliographicVolumeNumber": "36", "bibliographic_titles": [{"bibliographic_title": "生産研究"}]}]}, "item_4_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "吸着は一種の相変化であるため、これに伴い吸着熱の出入りがある。また、このことは、吸着平衡関係が温度によって大きく変化することを示している。これらの現象を利用する吸着冷房システム、吸着によるヒートポンプの可能性について、吸着平衡の観点から検討を加える", "subitem_description_type": "Abstract"}]}, "item_4_full_name_3": {"attribute_name": "著者別名", "attribute_value_mlt": [{"nameIdentifiers": [{"nameIdentifier": "39455", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "SAKODA, Akiyoshi"}]}, {"nameIdentifiers": [{"nameIdentifier": "39456", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "SUZUKI, Motoyuki"}]}]}, "item_4_publisher_20": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "東京大学生産技術研究所"}]}, "item_4_source_id_10": {"attribute_name": "書誌レコードID", "attribute_value_mlt": [{"subitem_source_identifier": "AN00127075", "subitem_source_identifier_type": "NCID"}]}, "item_4_source_id_8": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0037105X", "subitem_source_identifier_type": "ISSN"}]}, "item_4_subject_15": {"attribute_name": "日本十進分類法", "attribute_value_mlt": [{"subitem_subject": "430", "subitem_subject_scheme": "NDC"}]}, "item_4_text_21": {"attribute_name": "出版者別名", "attribute_value_mlt": [{"subitem_text_value": "Institute of Industrial Science, the University of Tokyo"}]}, "item_4_text_34": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"subitem_text_value": "Departmental Bulletin Paper"}]}, "item_4_text_4": {"attribute_name": "著者所属", "attribute_value_mlt": [{"subitem_text_value": "東京大学生産技術研究所第4部 化学工学"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "迫田, 章義"}], "nameIdentifiers": [{"nameIdentifier": "39453", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "鈴木, 基之"}], "nameIdentifiers": [{"nameIdentifier": "39454", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2017-06-08"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "sk036005001.pdf", "filesize": [{"value": "642.1 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 642100.0, "url": {"label": "sk036005001.pdf", "url": "https://repository.dl.itc.u-tokyo.ac.jp/record/20171/files/sk036005001.pdf"}, "version_id": "1731d228-1114-4f6b-9a52-3f0fcd758a37"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "departmental bulletin paper", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "研究解説 : 低温度熱源を利用する吸着冷房システム", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "研究解説 : 低温度熱源を利用する吸着冷房システム"}]}, "item_type_id": "4", "owner": "1", "path": ["1540", "1541"], "permalink_uri": "http://hdl.handle.net/2261/38987", "pubdate": {"attribute_name": "公開日", "attribute_value": "2010-12-06"}, "publish_date": "2010-12-06", "publish_status": "0", "recid": "20171", "relation": {}, "relation_version_is_last": true, "title": ["研究解説 : 低温度熱源を利用する吸着冷房システム"], "weko_shared_id": null}
研究解説 : 低温度熱源を利用する吸着冷房システム
http://hdl.handle.net/2261/38987
http://hdl.handle.net/2261/38987aa823d0a-67cb-4dcd-aca9-b56a275f94c4
名前 / ファイル | ライセンス | アクション |
---|---|---|
sk036005001.pdf (642.1 kB)
|
|
Item type | 紀要論文 / Departmental Bulletin Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2010-12-06 | |||||
タイトル | ||||||
タイトル | 研究解説 : 低温度熱源を利用する吸着冷房システム | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源 | http://purl.org/coar/resource_type/c_6501 | |||||
タイプ | departmental bulletin paper | |||||
その他のタイトル | ||||||
その他のタイトル | Adsorption Cooling by Utilizing Low-Temperature Heat | |||||
著者 |
迫田, 章義
× 迫田, 章義× 鈴木, 基之 |
|||||
著者別名 | ||||||
識別子 | 39455 | |||||
識別子Scheme | WEKO | |||||
姓名 | SAKODA, Akiyoshi | |||||
著者別名 | ||||||
識別子 | 39456 | |||||
識別子Scheme | WEKO | |||||
姓名 | SUZUKI, Motoyuki | |||||
著者所属 | ||||||
著者所属 | 東京大学生産技術研究所第4部 化学工学 | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | 吸着は一種の相変化であるため、これに伴い吸着熱の出入りがある。また、このことは、吸着平衡関係が温度によって大きく変化することを示している。これらの現象を利用する吸着冷房システム、吸着によるヒートポンプの可能性について、吸着平衡の観点から検討を加える | |||||
書誌情報 |
生産研究 巻 36, 号 5, p. 205-214, 発行日 1984-05-01 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0037105X | |||||
書誌レコードID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AN00127075 | |||||
日本十進分類法 | ||||||
主題 | 430 | |||||
主題Scheme | NDC | |||||
出版者 | ||||||
出版者 | 東京大学生産技術研究所 | |||||
出版者別名 | ||||||
Institute of Industrial Science, the University of Tokyo |