WEKO3
アイテム
{"_buckets": {"deposit": "0f60e23f-84d4-4090-97ab-73055ca1a0d6"}, "_deposit": {"id": "22991", "owners": [], "pid": {"revision_id": 0, "type": "depid", "value": "22991"}, "status": "published"}, "_oai": {"id": "oai:repository.dl.itc.u-tokyo.ac.jp:00022991", "sets": ["2082", "2083"]}, "item_4_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "1962-09-01", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "9", "bibliographicPageEnd": "308", "bibliographicPageStart": "304", "bibliographicVolumeNumber": "14", "bibliographic_titles": [{"bibliographic_title": "生産研究"}]}]}, "item_4_description_13": {"attribute_name": "フォーマット", "attribute_value_mlt": [{"subitem_description": "application/pdf", "subitem_description_type": "Other"}]}, "item_4_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "従来,工場などで使用していた継電器は,だいたい誘導型のもので,振動の多い現場で電動機個々に取りつけて保護する目的には適さなかったが,産業の近代化に伴い,不平衡負荷,欠相,および負荷の種類により過負荷のとき,瞬時にまたはある一定時間経過後継電器を動作させて電動機を保護したいとの種々の要求より,ツェナーダイオードの特性を利用して個々の要求を満たし,かつ回路を現場において,大きい温度変化に際しても安定した動作をする保護回路を試作した.", "subitem_description_type": "Abstract"}]}, "item_4_publisher_20": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "東京大学生産技術研究所"}]}, "item_4_source_id_10": {"attribute_name": "書誌レコードID", "attribute_value_mlt": [{"subitem_source_identifier": "AN00127075", "subitem_source_identifier_type": "NCID"}]}, "item_4_source_id_8": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0037105X", "subitem_source_identifier_type": "ISSN"}]}, "item_4_subject_15": {"attribute_name": "日本十進分類法", "attribute_value_mlt": [{"subitem_subject": "500", "subitem_subject_scheme": "NDC"}]}, "item_4_text_21": {"attribute_name": "出版者別名", "attribute_value_mlt": [{"subitem_text_value": "Institute of Industrial Science. University of Tokyo"}]}, "item_4_text_34": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"subitem_text_value": "Departmental Bulletin Paper"}]}, "item_4_text_4": {"attribute_name": "著者所属", "attribute_value_mlt": [{"subitem_text_value": "東京大学生産技術研究所 通信機器学"}, {"subitem_text_value": "Institute of Industrial Science. University of Tokyo"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "石橋, 泰雄"}], "nameIdentifiers": [{"nameIdentifier": "115073", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "市川, 初男"}], "nameIdentifiers": [{"nameIdentifier": "115074", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "関口, 豊"}], "nameIdentifiers": [{"nameIdentifier": "115075", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2017-06-26"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "sk014009003.pdf", "filesize": [{"value": "638.5 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 638500.0, "url": {"label": "sk014009003.pdf", "url": "https://repository.dl.itc.u-tokyo.ac.jp/record/22991/files/sk014009003.pdf"}, "version_id": "3efab541-5022-49ab-9884-83259316f00d"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "departmental bulletin paper", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "ツェナーダイオードの保護回路への応用", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "ツェナーダイオードの保護回路への応用"}]}, "item_type_id": "4", "owner": "1", "path": ["2082", "2083"], "permalink_uri": "http://hdl.handle.net/2261/31168", "pubdate": {"attribute_name": "公開日", "attribute_value": "2009-12-24"}, "publish_date": "2009-12-24", "publish_status": "0", "recid": "22991", "relation": {}, "relation_version_is_last": true, "title": ["ツェナーダイオードの保護回路への応用"], "weko_shared_id": null}
ツェナーダイオードの保護回路への応用
http://hdl.handle.net/2261/31168
http://hdl.handle.net/2261/3116804d9fb46-3aeb-4a11-a381-028af31ef56a
名前 / ファイル | ライセンス | アクション |
---|---|---|
sk014009003.pdf (638.5 kB)
|
|
Item type | 紀要論文 / Departmental Bulletin Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2009-12-24 | |||||
タイトル | ||||||
タイトル | ツェナーダイオードの保護回路への応用 | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源 | http://purl.org/coar/resource_type/c_6501 | |||||
タイプ | departmental bulletin paper | |||||
著者 |
石橋, 泰雄
× 石橋, 泰雄× 市川, 初男× 関口, 豊 |
|||||
著者所属 | ||||||
著者所属 | 東京大学生産技術研究所 通信機器学 | |||||
著者所属 | ||||||
著者所属 | Institute of Industrial Science. University of Tokyo | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | 従来,工場などで使用していた継電器は,だいたい誘導型のもので,振動の多い現場で電動機個々に取りつけて保護する目的には適さなかったが,産業の近代化に伴い,不平衡負荷,欠相,および負荷の種類により過負荷のとき,瞬時にまたはある一定時間経過後継電器を動作させて電動機を保護したいとの種々の要求より,ツェナーダイオードの特性を利用して個々の要求を満たし,かつ回路を現場において,大きい温度変化に際しても安定した動作をする保護回路を試作した. | |||||
書誌情報 |
生産研究 巻 14, 号 9, p. 304-308, 発行日 1962-09-01 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0037105X | |||||
書誌レコードID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AN00127075 | |||||
フォーマット | ||||||
内容記述タイプ | Other | |||||
内容記述 | application/pdf | |||||
日本十進分類法 | ||||||
主題 | 500 | |||||
主題Scheme | NDC | |||||
出版者 | ||||||
出版者 | 東京大学生産技術研究所 | |||||
出版者別名 | ||||||
Institute of Industrial Science. University of Tokyo |