ガラスビード法による蛍光X線分析装置(XRF)を用いた珪酸塩岩石の主・微量成分分析
https://doi.org/10.15083/0000032410
https://doi.org/10.15083/0000032410b393b2a8-1894-47f8-8090-7ca638210c50
名前 / ファイル | ライセンス | アクション |
---|---|---|
IHO90101.pdf (1.9MB)
|
|
Item type | 紀要論文 / Departmental Bulletin Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2016-06-15 | |||||
タイトル | ||||||
タイトル | ガラスビード法による蛍光X線分析装置(XRF)を用いた珪酸塩岩石の主・微量成分分析 | |||||
言語 | ja | |||||
言語 | ||||||
言語 | jpn | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | X-ray Fluorescence Spectrometer | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 1 : 5 dilution glass bead | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | silicate rocks | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | major and trace element analysis | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | departmental bulletin paper | |||||
ID登録 | ||||||
ID登録 | 10.15083/0000032410 | |||||
ID登録タイプ | JaLC | |||||
その他のタイトル | ||||||
その他のタイトル | Major and Trace Element Analysis of Silicate Rocks using Fused Glass Beads with an X-ray Fluorescence Spectrometer | |||||
著者 |
外西, 奈津美
× 外西, 奈津美× 安田, 敦× 中田, 節也 |
|||||
著者別名 | ||||||
識別子Scheme | WEKO | |||||
識別子 | 72481 | |||||
姓名 | Hokanishi, Natsumi | |||||
著者別名 | ||||||
識別子Scheme | WEKO | |||||
識別子 | 72482 | |||||
姓名 | Yasuda, Atsushi | |||||
著者別名 | ||||||
識別子Scheme | WEKO | |||||
識別子 | 72483 | |||||
姓名 | Nakada, Setsuya | |||||
著者所属 | ||||||
値 | 東京大学地震研究所 | |||||
著者所属 | ||||||
値 | 東京大学地震研究所 | |||||
著者所属 | ||||||
値 | 東京大学地震研究所 | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Quantitative analytical method was established for X-ray Fluorescence Spectrometer (XRF) using a fused glass bead of silicate rock powder diluted with lithium-tetraborate at a ratio of 1 : 5. It takes approximately 80 minutes to measure 10 major and 18 trace elements on one glass bead. Calibration lines constructed with 26 reference rock standards provide good accuracy and precision for elements with the exception of La. To confirm the quality of this analytical method, four reference rock standards (JA-2, JB-1 a, JG-1 a, and JR-2), which are not used for constructing the calibration lines, are measured as unknown samples. The analytical results agree well with recommended values. The stability of the instrument is evaluated by repeating measurements of the glass beads, JB-1 a and JG-1 a. The standard deviation of the results of 10 repeated measurements reveals fluctuations were below 0.02 wt. % for all major elements except SiO2. The standard deviation for SiO2 is slightly higher, i.e. 0.09- 0.12 wt. %, but the coefficient of variation for SiO2 is 0. 2%, which is small compared to other major elements. Analytical results for trace elements of the four reference rock standards agree well with their reported values, with the exception of Ba. Low precision and stability of Ba measurement derive from low X-ray intensity (L-spectrum) of Ba at the analytical conditions applied. | |||||