WEKO3
アイテム
{"_buckets": {"deposit": "19119a75-7697-4b98-bbfb-06fc073828a2"}, "_deposit": {"id": "4328", "owners": [], "pid": {"revision_id": 0, "type": "depid", "value": "4328"}, "status": "published"}, "_oai": {"id": "oai:repository.dl.itc.u-tokyo.ac.jp:00004328", "sets": ["234", "256"]}, "item_7_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2012-09-27", "bibliographicIssueDateType": "Issued"}, "bibliographic_titles": [{}]}]}, "item_7_date_granted_25": {"attribute_name": "学位授与年月日", "attribute_value_mlt": [{"subitem_dategranted": "2012-09-27"}]}, "item_7_degree_name_20": {"attribute_name": "学位名", "attribute_value_mlt": [{"subitem_degreename": "修士(環境学)"}]}, "item_7_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Particle image velocimetry (PIV) technique was applied to investigate the vibration response characteristics of two circular cylinders with same diameter in tandem arrangement and the flow field around them. The cylinders were mounted as cantilevers with low natural frequency (around 50Hz). The Reynolds number ranges from 4,000 to 20,000. The spacing between two cylinders was 20mm.", "subitem_description_type": "Abstract"}]}, "item_7_full_name_3": {"attribute_name": "著者別名", "attribute_value_mlt": [{"nameIdentifiers": [{"nameIdentifier": "9857", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "徐, 強"}]}]}, "item_7_select_21": {"attribute_name": "学位", "attribute_value_mlt": [{"subitem_select_item": "master"}]}, "item_7_subject_13": {"attribute_name": "日本十進分類法", "attribute_value_mlt": [{"subitem_subject": "423", "subitem_subject_scheme": "NDC"}]}, "item_7_text_24": {"attribute_name": "研究科・専攻", "attribute_value_mlt": [{"subitem_text_value": "新領域創成科学研究科環境学研究系人間環境学専攻"}]}, "item_7_text_27": {"attribute_name": "学位記番号", "attribute_value_mlt": [{"subitem_text_value": "修創域第4527号"}]}, "item_7_text_36": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"subitem_text_value": "Thesis"}]}, "item_7_text_4": {"attribute_name": "著者所属", "attribute_value_mlt": [{"subitem_text_value": "東京大学大学院新領域創成科学研究科環境学研究系人間環境学専攻"}, {"subitem_text_value": "Department of Human and Engineered Environmental Studies, Graduate School of Frontier Sciences, The University of Tokyo"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Xu, Qiang"}], "nameIdentifiers": [{"nameIdentifier": "9856", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2017-06-01"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "K-03619-a.pdf", "filesize": [{"value": "785.8 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 785800.0, "url": {"label": "要旨(summary)", "url": "https://repository.dl.itc.u-tokyo.ac.jp/record/4328/files/K-03619-a.pdf"}, "version_id": "3e7a9984-534e-4319-91d7-478ef199c975"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "PIV", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Flow field", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Two circular cylinders", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Vibration", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Fluctuation transfer velocity", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "thesis", "resourceuri": "http://purl.org/coar/resource_type/c_46ec"}]}, "item_title": "Experimental investigation on the flow field between two circular cylinders in tandem arrangement (Summary)", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Experimental investigation on the flow field between two circular cylinders in tandem arrangement (Summary)"}]}, "item_type_id": "7", "owner": "1", "path": ["234", "256"], "permalink_uri": "http://hdl.handle.net/2261/53244", "pubdate": {"attribute_name": "公開日", "attribute_value": "2013-02-18"}, "publish_date": "2013-02-18", "publish_status": "0", "recid": "4328", "relation": {}, "relation_version_is_last": true, "title": ["Experimental investigation on the flow field between two circular cylinders in tandem arrangement (Summary)"], "weko_shared_id": null}
Experimental investigation on the flow field between two circular cylinders in tandem arrangement (Summary)
http://hdl.handle.net/2261/53244
http://hdl.handle.net/2261/53244cf20bb5a-b979-4dfe-9590-eae35627e770
名前 / ファイル | ライセンス | アクション |
---|---|---|
要旨(summary) (785.8 kB)
|
|
Item type | 学位論文 / Thesis or Dissertation(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2013-02-18 | |||||
タイトル | ||||||
タイトル | Experimental investigation on the flow field between two circular cylinders in tandem arrangement (Summary) | |||||
言語 | ||||||
言語 | eng | |||||
キーワード | ||||||
主題 | PIV | |||||
主題Scheme | Other | |||||
キーワード | ||||||
主題 | Flow field | |||||
主題Scheme | Other | |||||
キーワード | ||||||
主題 | Two circular cylinders | |||||
主題Scheme | Other | |||||
キーワード | ||||||
主題 | Vibration | |||||
主題Scheme | Other | |||||
キーワード | ||||||
主題 | Fluctuation transfer velocity | |||||
主題Scheme | Other | |||||
資源タイプ | ||||||
資源 | http://purl.org/coar/resource_type/c_46ec | |||||
タイプ | thesis | |||||
著者 |
Xu, Qiang
× Xu, Qiang |
|||||
著者別名 | ||||||
識別子 | 9857 | |||||
識別子Scheme | WEKO | |||||
姓名 | 徐, 強 | |||||
著者所属 | ||||||
著者所属 | 東京大学大学院新領域創成科学研究科環境学研究系人間環境学専攻 | |||||
著者所属 | ||||||
著者所属 | Department of Human and Engineered Environmental Studies, Graduate School of Frontier Sciences, The University of Tokyo | |||||
Abstract | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Particle image velocimetry (PIV) technique was applied to investigate the vibration response characteristics of two circular cylinders with same diameter in tandem arrangement and the flow field around them. The cylinders were mounted as cantilevers with low natural frequency (around 50Hz). The Reynolds number ranges from 4,000 to 20,000. The spacing between two cylinders was 20mm. | |||||
書誌情報 | 発行日 2012-09-27 | |||||
日本十進分類法 | ||||||
主題 | 423 | |||||
主題Scheme | NDC | |||||
学位名 | ||||||
学位名 | 修士(環境学) | |||||
学位 | ||||||
値 | master | |||||
研究科・専攻 | ||||||
新領域創成科学研究科環境学研究系人間環境学専攻 | ||||||
学位授与年月日 | ||||||
学位授与年月日 | 2012-09-27 | |||||
学位記番号 | ||||||
修創域第4527号 |