{"_buckets": {"deposit": "4edd1d27-c12d-4d4e-a49a-9c1abd95aaa6"}, "_deposit": {"id": "32184", "owners": [], "pid": {"revision_id": 0, "type": "depid", "value": "32184"}, "status": "published"}, "_oai": {"id": "oai:repository.dl.itc.u-tokyo.ac.jp:00032184"}, "item_4_alternative_title_1": {"attribute_name": "\u305d\u306e\u4ed6\u306e\u30bf\u30a4\u30c8\u30eb", "attribute_value_mlt": [{"subitem_alternative_title": "Construction of the General Observation System for Strong Motion in Earthquake Research Institute"}]}, "item_4_biblio_info_7": {"attribute_name": "\u66f8\u8a8c\u60c5\u5831", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2007", "bibliographicIssueDateType": "Issued"}, "bibliographicPageEnd": "19", "bibliographicPageStart": "6", "bibliographicVolumeNumber": "13", "bibliographic_titles": [{"bibliographic_title": "\u6280\u8853\u7814\u7a76\u5831\u544a"}]}]}, "item_4_description_5": {"attribute_name": "\u6284\u9332", "attribute_value_mlt": [{"subitem_description": "The general observation system for strong motion on three-type buildings in Earthquake Research Institute has been constructed. This system consists of twelve accelerometers and a multi-channel data logger. The construction of a new building of Earthquake Research Institute was started at the end of 2004 fiscal year. The structure of the new building (Bldg. 1) was designed to be a seven-storied reinforced concrete building of pile foundation with seismic isolation system. Division of Disaster Mitigation Science of Earthquake Research Institute. proposed a basic plan of strong motion observation with settled accelerometers. The main feature of this observation plan is the settlement of accelerometers ; two in pile, one on the base of isolation system, two at the eastern and western ends of first floor, one at seventh floor, and one on the ground, for the purpose of verification to the seismic isolation system when earthquakes occur. The recorded seismic data are to be gathered by the highly efficient multi-channel data logger AJE-8200 (MITUTOYO) placed at the room 1-512 of bldg. 1 Three and two accelerometers were also settled in the old building (Bldgs. 2, 3) respectively.", "subitem_description_type": "Abstract"}]}, "item_4_description_6": {"attribute_name": "\u5185\u5bb9\u8a18\u8ff0", "attribute_value_mlt": [{"subitem_description": "\uff1c\u7dcf\u8aac\uff1e", "subitem_description_type": "Other"}]}, "item_4_full_name_3": {"attribute_name": "\u8457\u8005\u5225\u540d", "attribute_value_mlt": [{"nameIdentifiers": [{"nameIdentifier": "71646", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "SAKAUE, Minoru"}]}]}, "item_4_identifier_registration": {"attribute_name": "ID\u767b\u9332", "attribute_value_mlt": [{"subitem_identifier_reg_text": "10.15083/00032175", "subitem_identifier_reg_type": "JaLC"}]}, "item_4_publisher_20": {"attribute_name": "\u51fa\u7248\u8005", "attribute_value_mlt": [{"subitem_publisher": "\u6771\u4eac\u5927\u5b66\u5730\u9707\u7814\u7a76\u6240"}]}, "item_4_source_id_10": {"attribute_name": "\u66f8\u8a8c\u30ec\u30b3\u30fc\u30c9ID", "attribute_value_mlt": [{"subitem_source_identifier": "AA11602838", "subitem_source_identifier_type": "NCID"}]}, "item_4_source_id_8": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "13426486", "subitem_source_identifier_type": "ISSN"}]}, "item_4_text_21": {"attribute_name": "\u51fa\u7248\u8005\u5225\u540d", "attribute_value_mlt": [{"subitem_text_value": "Earthquake Research Institute\uff0cUniversity of Tokyo"}]}, "item_4_text_34": {"attribute_name": "\u8cc7\u6e90\u30bf\u30a4\u30d7", "attribute_value_mlt": [{"subitem_text_value": "Departmental Bulletin Paper"}]}, "item_4_text_4": {"attribute_name": "\u8457\u8005\u6240\u5c5e", "attribute_value_mlt": [{"subitem_text_value": "\u6771\u4eac\u5927\u5b66\u5730\u9707\u7814\u7a76\u6240\u6280\u8853\u90e8\u6280\u8853\u958b\u767a\u5ba4"}, {"subitem_text_value": "Laboratory for Technical Service and Development, Earthquake Research Institute, University of Tokyo"}]}, "item_creator": {"attribute_name": "\u8457\u8005", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "\u5742\u4e0a, \u5b9f"}], "nameIdentifiers": [{"nameIdentifier": "71645", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "\u30d5\u30a1\u30a4\u30eb\u60c5\u5831", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2017-06-12"}], "displaytype": "detail", "download_preview_message": "", "filename": "13_006-019.pdf", "filesize": [{"value": "2.0 MB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 20000000, "url": {"label": "13_006-019.pdf", "url": "https://repository.dl.itc.u-tokyo.ac.jp/record/32184/files/13_006-019.pdf"}, "version_id": "f9b77867-c024-4092-93c0-4bad8c1008ea"}]}, "item_keyword": {"attribute_name": "\u30ad\u30fc\u30ef\u30fc\u30c9", "attribute_value_mlt": [{"subitem_subject": "reinforced concrete building", "subitem_subject_scheme": "Other"}, {"subitem_subject": "seismic isolation system", "subitem_subject_scheme": "Other"}, {"subitem_subject": "strong motion observation", "subitem_subject_scheme": "Other"}, {"subitem_subject": "highly efficient multi-channel data logger", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "\u8a00\u8a9e", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "\u8cc7\u6e90\u30bf\u30a4\u30d7", "attribute_value_mlt": [{"resourcetype": "departmental bulletin paper", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "\u5730\u9707\u7814\u7a76\u6240\u7dcf\u5408\u5f37\u9707\u89b3\u6e2c\u30b7\u30b9\u30c6\u30e0\u306e\u69cb\u7bc9", "item_titles": {"attribute_name": "\u30bf\u30a4\u30c8\u30eb", "attribute_value_mlt": [{"subitem_title": "\u5730\u9707\u7814\u7a76\u6240\u7dcf\u5408\u5f37\u9707\u89b3\u6e2c\u30b7\u30b9\u30c6\u30e0\u306e\u69cb\u7bc9"}]}, "item_type_id": "4", "owner": "1", "path": ["80/4453/4473", "9/504/4455/4474"], "permalink_uri": "https://doi.org/10.15083/00032175", "pubdate": {"attribute_name": "\u516c\u958b\u65e5", "attribute_name_i18n": "\u516c\u958b\u65e5", "attribute_value": "2017-05-15"}, "publish_date": "2017-05-15", "publish_status": "0", "recid": "32184", "relation": {}, "relation_version_is_last": true, "title": ["\u5730\u9707\u7814\u7a76\u6240\u7dcf\u5408\u5f37\u9707\u89b3\u6e2c\u30b7\u30b9\u30c6\u30e0\u306e\u69cb\u7bc9"], "weko_shared_id": null}
  1. 131 地震研究所
  2. 東京大学地震研究所技術研究報告
  3. 13
  1. 0 資料タイプ別
  2. 30 紀要・部局刊行物
  3. 東京大学地震研究所技術研究報告
  4. 13

地震研究所総合強震観測システムの構築

https://doi.org/10.15083/00032175
fa933b30-1bb1-4312-9b9d-ea08bbc09665
プレビュー
名前 / ファイル ライセンス Actions
13_006-019.pdf 13_006-019.pdf (2.0 MB)
item type 紀要論文 / Departmental Bulletin Paper(1)
公開日 2017-05-15
タイトル
タイトル 地震研究所総合強震観測システムの構築
言語
言語 jpn
キーワード
主題Scheme Other
主題 reinforced concrete building
キーワード
主題Scheme Other
主題 seismic isolation system
キーワード
主題Scheme Other
主題 strong motion observation
キーワード
主題Scheme Other
主題 highly efficient multi-channel data logger
資源タイプ
資源 http://purl.org/coar/resource_type/c_6501
タイプ departmental bulletin paper
ID登録
ID登録 10.15083/00032175
ID登録タイプ JaLC
その他のタイトル
その他のタイトル Construction of the General Observation System for Strong Motion in Earthquake Research Institute
著者 坂上, 実

× 坂上, 実

WEKO 71645

坂上, 実

Search repository
著者別名
姓名
姓名 SAKAUE, Minoru
著者所属
東京大学地震研究所技術部技術開発室
著者所属
Laboratory for Technical Service and Development, Earthquake Research Institute, University of Tokyo
抄録
内容記述タイプ Abstract
内容記述 The general observation system for strong motion on three-type buildings in Earthquake Research Institute has been constructed. This system consists of twelve accelerometers and a multi-channel data logger. The construction of a new building of Earthquake Research Institute was started at the end of 2004 fiscal year. The structure of the new building (Bldg. 1) was designed to be a seven-storied reinforced concrete building of pile foundation with seismic isolation system. Division of Disaster Mitigation Science of Earthquake Research Institute. proposed a basic plan of strong motion observation with settled accelerometers. The main feature of this observation plan is the settlement of accelerometers ; two in pile, one on the base of isolation system, two at the eastern and western ends of first floor, one at seventh floor, and one on the ground, for the purpose of verification to the seismic isolation system when earthquakes occur. The recorded seismic data are to be gathered by the highly efficient multi-channel data logger AJE-8200 (MITUTOYO) placed at the room 1-512 of bldg. 1 Three and two accelerometers were also settled in the old building (Bldgs. 2, 3) respectively.
内容記述
内容記述タイプ Other
内容記述 <総説>
書誌情報 技術研究報告

巻 13, p. 6-19, 発行日 2007
ISSN
収録物識別子タイプ ISSN
収録物識別子 13426486
書誌レコードID
収録物識別子タイプ NCID
収録物識別子 AA11602838
出版者
出版者 東京大学地震研究所
出版者別名
Earthquake Research Institute,University of Tokyo
Back
0
views
See details
Views

Versions

Ver.1 2021-03-01 10:52:49.441315
Show All versions

Share

Mendeley CiteULike Twitter Facebook Print Addthis

Cite as

Export

OAI-PMH
  • OAI-PMH JPCOAR
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by CERN Data Centre & Invenio


Powered by CERN Data Centre & Invenio